500W Led Site Floodlights

  • 500W Led Site Floodlights
  • 500W Led Site Floodlights
  • 500W Led Site Floodlights
500W Led Site Floodlights
  • Led stadium light
  • China
  • 3-5days
  • 600000pcs Per month

This Flood Light has 10W chips installed. As there is more power in each individual chip, less chips are required to produce the same overall high-power output with a smaller size.
The light efficiency is extremely high, reaching 160lm/W with DLC Premium. Lenses are premium, with very accurate optics.
Widely used in Stadiums, Sports Facilities, Tunnels, Squares, High Mast Lighting, Light Towers, Ports,High speed photographic ect.

500W Site LED Flood Light

led site floodlights


Main Features

Luminous Efficiency: 160 lm/W (190 lm/W7WVersion)

IP Rating: IP66 approved (IP67 and IP68 supported)

Life Span: >80000 hours

Work Temperature:-25 °C to  60 °C                               

Warranty Period: 5 Years                                                           

Powers Available: 100W to 5000W


Part No.WattageLamp LumenFluxCCTBeam AngleVoltage
RT-BLLF100W100Watt

America Bridgelux 160lm/W         

America CREE

16000lm3000K,3500K,4000K,5000K,5700K,6500K10-25-40-60-90DegreeMeanwell driver                 90-295VAC           
RT-BLLF150W150Watt24000lm
RT-BLLF200W200Watt32000lm
RT-BLLF240W240Watt38400lm
RT-BLLF300W300Watt48000lm
RT-BLLF360W360Watt57600lm
RT-BLLF400W400Watt64000lm
RT-BLLF500W500Watt80000lm
RT-BLLF720W720Watt115200lm
RT-BLLF1000W1000Watt160000lm
RT-BLLF1500W1500Watt240000lm
RT-BLLF2000W2000Watt320000lm
RT-BLLF4000W4000Watt640000lm


Technical Parameter

Light Source: USA original Bridgelux Chip(upto 199lm/W)

Power Supply: MeanWell or Inventronics

Color Index(CRI): Ra> 80 (until 96)

Input Voltage: 90-295VAC 50-60HZ                                

Power Factor (PF): >0.95      

Power Efficiency: >90%

Beam angles available: 10°, 25°, 40°, 60° 90°, 120°


500W LED Flood Light Drawing:

outdoor flood lights

What Kind of lights are used for site and requirements?


The lighting problem at night is a very important consideration for the site, which needs to be continuously operated day and night.Because if there is no proper light and lighting at night, it will have a great impact on our site work.At the same time because the general area of the site are very large, so the commonly used light source for the site is not feasible.So the following to introduce to you, in the end site lighting needs to use what kind of lights and some requirements for site lighting.


outdoor led flood lights


What lights are used for site lighting?

Common light bulbs and portable "working hand lamps" are used for local lighting.Iodine tungsten lamps for small area lighting;Be used in large area illume, now commonly use "dysprosium lamp" (belong to gas discharge kind lamp), it has 1000W and 3500W commonly two kinds are more practical, its advantage is: power is big, but energy efficiency ratio is high.If a 3500W dysprosium lamp is installed on an elevated structure, its brightness is within the range of 1000 square meters, and the rose falling on the ground can be found. Therefore, most of the night construction sites now use this kind of lamp.


However, such traditional lamps are generally of high power and high electricity cost, so our 1000W site Flood light can completely replace them.It only needs 1/3 power, but the brightness is 3-6times higher.


led site floodlights

Site Flood lighting requirements

(1) General place, lighting voltage should be 220V.

(2) Tunnel, civil air defense engineering, high temperature, conductive dust and narrow places, lighting voltage should not be greater than 36V.

(3) damp and easy to touch lighting line, lighting voltage should not be greater than 24V.

(4) especially damp, good conductivity of the ground, boiler or metal containers, lighting voltage should not be greater than 12V.

(5) The line lamp voltage should not be greater than 36V.

(6) The scene of the lighting line, must use soft rubber sheathed wire, and equipped with leakage protector protection.The metal housing of the luminaire shall be ground (zero) protected.

(7) The phase line of the floodlight should be controlled by the switch and not directly introduced.

(8) Must implement the "one machine, one switch" system, it is strictly prohibited to use the same switch directly control two and more than two sets of electrical equipment (including socket).

(9) Overhead lines must use insulated copper wire or insulated aluminum wire.

(10) The metal support of movable iodine tungsten lamp shall be reliably grounded (zero), and the height of the lamp shall not be lower than 2.5m from the ground.

(11) The mounting bracket of High Power Site Flood Light shall be solid and reliable, and rainproof measures shall be taken.

(12) Being construction lighting lamps and lanterns is apart from the ground shall be not less than 3 m, outdoor indoor lamps and lanterns is apart from the ground shall be not less than 2.5 m.

(13) Levies construction lighting use 220 v flood light should be fixed installation, its height should not be less than 3 m, away from combustible materials shall not be less than 500 mm, and shall not be direct illuminate tinder.

(14) construction electricity lighting appliance form and the degree of protection should be adapted to the environmental conditions.

(15) need construction sites or the dark night, you must configure emergency lighting power supply.

(16) Night may affect pedestrians, vehicles, aircraft and other safe passage construction sites or facilities, equipment, you must set up red alert light.

Summary: in the above article for everyone to introduce the general lighting site with what kind of lights, in general site lighting needs to use the lights, the biggest characteristic is that its wattage must be high, because only high wattage can ensure that our site can be illuminated.In addition to our watts to be high, in fact, there are a lot of requirements for site lighting lights need us to pay attention to, I hope you can refer to these requirements before choosing to use their own site lights.




Delivery
LED Stadium Light Shipment
FAQ
LED Flood light Features and advantages
Features and advantages of Reita LED flood lights: Features: 1. The internal and external strong earthquake resistant structure design is adopted to effectively solve the problems of bulb shedding, bulb life shortening and bracket fracture caused by strong vibration. 2, with high efficiency gas discharge lamp as the light source, the bulb service life of more than 10,000 hours, especially suita...more
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right